Product Description
Rinnai RL94i (REU-VC2837FFUD-US) Luxury Series Interior Tankless Water Heatermax Btu 190,000 max flow 9.8 gpm with Isolation Valve
- ENERGY STAR Qualified
- Energy Factor of .82 for Natural Gas and Propane
- Built-in Rinnai Circ-LogicTM recirculation program cycles an external pump at pre-set intervals and temperatures to maximize efficiency and comfort (see brochure for more details)
- Certified for Installation in Manufactured (Mobile) Homes
- Enhanced scale detection lessens possibility of serious, long-term damage to unit
- Temperature lock function prevents accidental or unauthorized changes to water temperature
Dimensions
|
Width: 14 Inches
Height: 23 Inches
Depth: 9.3 Inches
|
---|---|
Weight
|
46 Pounds
|
Ignition
|
Direct Electronic
|
Hot Water Capacity
|
0.26 to 9.8 GPM
|
Minimum Activation Rate
|
0.4 GPM
|
Minimum/Maximum Gas Rate (Input BTUs)
|
10,300 – 199,000
|
Energy Factor
|
0.82 for Natural Gas and Propane
|
Energy Star
|
Yes
|
Approved Gas Types
|
Natural Gas or Propane
|
Temperature Settings
|
98°F – 140°F with MC-91-2US
98° F – 185° F with MCC-91-2US
|
Type of Controller
|
MC-91-2US (included)
MCC-91-2US (optional for Commercial or Hydronic Applications)
MC-100V-1US Deluxe Controller (optional)
BC-100V-1US Bathroom Controller (optional)
|
Ultra Lox NOx
|
No
|
Electrical
|
AC 120 Volts, 60 Hz
|
Electrical Consumption
|
Normal: 97 Watts
Standby: 2 Watts
Anti-Frost Protection: 120 Watts
|
Service Connections
|
Gas Supply: 3/4 Inch MNPT
Cold Water Inlet: 3/4 Inch MNPT
Hot Water Outlet: 3/4 Inch MNPT
|
Specifications: |
|
Type of Appliance: | • Temperature Controlled, Continuous Flow, Gas Hot Water System
• Certified for installation in Manufactued (Mobile) homes • Forced combustion / Direct vent • Energy Star Qualified. |
Rinnai Model Number: | REU-VC2837FFUD-US |
Installation: | Indoor only |
Minimum/Maximum Gas Rate (Input): | 10,300 – 199,000 BTU/h (3.02-56.3kW) |
Electrical: | Appliance: AC 120 Volts – 60 Hz; Temperature Controller: DC 12 Volts |
Electrical Consumption: | Normal: 97 w Stanby: 2 w Anti-frost Protection: 120 w |
Ignition System: | Direct electronic ignition |
Hot Water Capacity: | Minimum flow rate: 0.26 GPM (1 l/min) |
Minimum activation flow rate: 0.4 GPM 1.5 l/min) | |
Maximum flow rate: 9.8 GPM (37.1 l/min) | |
Temperature: | 98° – 120° F (37° – 49°C) (factory default) Maximum temperature is selectable at 120°F(49°C) or at 140°F(60°C); 98°-185°F (37°-85°C) available with the MCC-91-2 controller for commercial and hydronic applications |
Temperature (without Remote): | 120° F (49°C) (factory default) or 140° F (60°C) |
Energy Factor (FE): | Natural Gas: 0.82; Propane: 0.82 |
Service Connections: | Gas supply: 3/4 inch (19mm) MNPT |
Cold water inlet: 3/4 inch (19mm) MNPT | |
Hot water outlet: 3/4 inch (19mm) MNP | |
Isolation & Pressure Relief Valves
Included: |
Heavy duty forged brass Webstone Isolator valves EXP E2, certified to NSF/ANSI 61-8 for potable water, rated up to 200,000BTU and 15o PSI |
Water Flow Control: | Water flow sensor, electronic water control and by-pass control |
Minimum/Maximum Water Supply
Pressure: |
20-150 PSI (138-1035 KPa) (30-80 PSI (207-552 KPa) is recommended for maximum performance) |
Water Temperature Control: | Simulation feed forward and feedback |
Controller: | MC-91-2US (part of the front panel) |
MCC-91-2US (Optional, for hydronic and commercial applications) | |
Deluxe controller: MC-100V-1US (optional) | |
Bathroom controller: BC-100V-1US (optional) | |
Controller Cable: | Non-polarized two-core cable, minimum 22 AWG |
Safety Devices: | Flame failure – Flame Rod Remaining flame (OHS) |
Boiling protection Thermal fuse | |
Combustion fan rpm check Automatic frost protection | |
Over current – glass fuse | |
Clearances from Combustibles: | Top of heater – 6 Inches (152.4mm) Back of heater – 0 Inches |
Front of heater – 6 Inches (152.4mm) Bottom of Heater – 12 Inches (304.8mm) | |
Sides of heater – 2 Inches (50.8mm) From vent pipe – 0 inches | |
Clearances from
Non-Combustibles: |
Top of heater – 2 Inches (50.8mm) Back of heater – 0 Inches |
Front of heater – 6 Inches (152.4mm) Bottom of Heater – 12 Inches (304.8mm) | |
Sides of heater – 1/2 Inches (12.7mm) From vent pipe – 0 inches | |
Min./Max. Gas Supply Pressure
(sea level): |
Natural Gas: min 5” W.C. max 10.5” W.C.
Propane: min 8″ W.C. max 13.5″ W.C. |
Manifold Gas Pressure
(inches W.C.): |
Natural Gas: high fire 3.0” W.C. low fire 0.61” W.C.
Propane Gas: high fire 4.8” W.C low fire 0.87” W.C. |
NOx: | Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission level |
SKU: RL94i REU-VC2837FFUD-US REUVC2837FFUDUS